DOI: https://doi.org/10.15407/publishing2018.49.098
ERRORS OF COAXIAL-CYLINDRICAL TRANCDUCERS FOR CAPACITANCE LEVELMEATERS
F.B. Grynevych, A.M. Savoluik Institute of Electrodynamics of the National Academy of Sciences of Ukraine, Peremohy, 56, Kyiv-57, 03680, Ukraine, е-mail:
This e-mail address is being protected from spambots. You need JavaScript enabled to view it
The questions of accuracy of coaxial-cylindrical level sensors are considered, simplified expression, table for practical assessment of parameters and value errors are obtained. References 11, table 1. Key words: capacitance, liquid, level, error.
1. Ershov M.N. Methods for measuring the level of liquid products: theory and practice. Izvestiya Tulskogo gosudarstvennogo universiteta. Tekhnicheskie nauki. 2010. № 4-1. P. 9–14. (Rus) 2. Vilnina A.V., Vilnin A.D., Efremov E.V. Modern methods and means for level measurement in the chemical industry. Publishing house of Tomsk Polytechnic University. 2011. 84 p. (Rus) 3. Karandeev K.B., Grinevich F.B., Novik A.I.. Capacitive self-compensated level indicators. Moscwa, Leningrad: Energiya, 1966. 135 p. (Rus) 4. Fraden. Modern sensors. Moskva: Tekhnosfera. 2006. 588 p. (Rus) 5. Khansuvarov K.I., Tseytlin V.G.. Technique of measuring pressure, flow, level of liquids, gas and steam. Moskva: Izdatelstvo standartov, 1990. 287 p. 6. Brindley K. Sensors and Transducers. Moscwa: Energoatomizdat, 1991. 144 p. (Rus) 7. Bobrovnikov G.N., A.G. Katkov A.G. Level measurement methods. Moskva: Mashynostroenie, 1977. 168 p. (Rus) 8. Grinevych F.B., Levitskyi A.S., Konopko V.I. An influence of electrodes’ skew of a cylindrical primary transducer (sensor) on the measurement accuracy of displacements. Tekhnicheskaya elektrodinamika. 1979. № 2. P. 83–85. (Rus) 9. Grinevich F.B., A.S. Levitskyi A.S., Konopko V.I. Error calculation of a cylindrical primary transducer (sensor) of a displacement caused by mutual parallel displacement of the axis of cylinder-electrodes. Tekhnicheskaya elektrodinamika. 1979. № 1. P. 88–91. (Rus) 10. Monastyrskyi Z.Ya., Savoliuk A.M. Compensation of the effect of coaxial-cylindrical capacitive level sensors on a measurement accuracy of technological errors. Tekhnicheskaya elektrodinamika. 1986. № 1. P. 94–101. (Rus) 11. Savliuk A.M.. Errors as a result of the interaction of capacitive measuring level sensors with a controlled medium. Tekhnicheskaya elektrodinamika. 1992. № 5. P. 100–107. (Rus)
|